The ultimate temperature control solution for centrifugal air compressors
The Ingersoll Rand Centac Cooler C700 is a core module specifically built for Centac series centrifugal air compressors. Its primary function is to cool high-temperature lubricating oil or compressed air generated during compression to optimal temperatures through advanced heat exchange technology, ensuring efficient and stable equipment operation.
As a critical module in oil-free centrifugal compressor systems, the C700 cooler serves as a "temperature guardian" in industrial applications, effectively preventing operational performance degradation, increased energy consumption, and minimized equipment lifespan caused by excessive heat. The Ingersoll Rand Centac series centrifugal compressors are widely used in electronics, pharmaceuticals, petrochemicals, power generation, and automotive manufacturing industries where compressed air purity and stability are paramount.
The C700 cooler keep precise temperature control to help ensure compliance with ISO 8573-1 Class 0 oil-free standards, provide high-quality compressed air. Its compact, efficient design and exceptional energy operational performance make it a preferred cooling offering in industrial use cases.
| Cooling overall efficiency | Multi-stage counterflow design with 80-120m² heat transfer area achieves over 90% temperature reduction overall efficiency (85°C inlet to 50°C outlet at 150L/min flow rate) |
| Heat Transfer Coefficient | 600-700W/(m²·℃) for copper tube design with oil-side pressure loss ≤0.02MPa and water-side ≤0.03MPa |
| Heat Load Capacity | Maximum 2000kW capacity for high-load continuous operation |
| Core Materials | T2 copper tubes with 0.2mm aluminum fins (398W/(m·K conductivity), 5.5MPa pressure tested; 316L stainless steel version supply 3x better chloride resistance |
| Flow Path Design | 8-12mm oil channels and 10-15mm water channels with 2.5-4.5m/s flow velocity to minimize fouling |
| Sealing system setup | Quadruple-seal design (graphite ring + mechanical seal + O-ring + lip seal) with ≤0.02SCFM leakage and ≥99.999% oil-gas separation overall efficiency |
| Operating Pressure | 0.8-3.0MPa (gauge), max 3.5MPa working pressure, 7.0MPa burst pressure |
| Oil Flow Range | 100-1000L/min with ±0.5°C outlet temperature stability during ±5% flow fluctuations |
| Water-side operational performance | 20-100m³/h flow rate, ≤0.06MPa resistance, ≤0.0001m²·℃/W fouling factor, ≤50ppm CaCO₃ water hardness recommended |
| Specific Power | 4.5-6.0 kW/100m³/min (30-35% more efficient than two-stage compression) |
| Waste Heat Recovery | 150-300kW heat recovery potential via ORC system setups, generating 1-2 million kWh/year (750-1500 tons CO₂ reduction) |
| Oil-free Certification | ISO 8573-1 Class 0 compliant (≤0.003mg/m³ oil content, ≤3 particles/m³ at 0.1μm) |
Challenge: Semiconductor manufacturer requiring ultra-pure compressed air
offering: Centac Cooler C700 with Centac C700 compressor
Results: 48-50°C stable outlet temperature, ≤0.001mg/m³ oil content, 25% energy savings (1.8 million kWh/year), 1350-ton CO₂ reduction
Challenge: Biopharma company needing oil-free air for fermentation
offering: C700 cooler ensuring ISO 8573-1 Class 0 air quality
Results: 30% lower maintenance costs with stable production safety
Challenge: Refinery requiring 2.5MPa compressed air
offering: High-pressure C700 cooler system setup
Results: ±0.3°C temperature stability, 40% less lubricant consumption
Challenge: Gas turbine plant needing dry air supply
offering: C700 cooler with heat recovery
Results: 15% output increase, 3.5% lower heat rate, 80GWh additional annual generation
| Coolant Monitoring | Daily checks: pH (7.0-7.8), conductivity (≤300μS/cm), hardness (≤40ppm CaCO₃) |
| Leak Detection | Monthly helium leak tests (≤2×10⁻¹⁰Pa·m³/s rate) |
| Vibration Analysis | Quarterly checks: ≤0.7mm/s axial, ≤1.4mm/s radial vibration |
| 500 Hours | Replace corrosion inhibitor (65ppm), clean 10μm water filters, check 650N fan belt tension |
| 2000 Hours | Test safety valves (1.05× working pressure), replace oil separator elements (>0.032MPa ΔP) |
| 8000 Hours | Change ISO VG 46 synthetic oil (acid value ≤0.30mgKOH/g), clean thermal exchanger fins |
The Ingersoll Rand Centac Cooler C700 sets industry benchmarks with 90% cooling overall efficiency, 2000kW heat capacity, and ISO Class 0 compliance. Through proper maintenance and upgrades, users achieve 40% longer lifespan and 30% energy savings. As Industry 4.0 advances, the C700 evolves with smart monitoring and green technology integration. AirsCooler provides complete lifecycle support to fine-tune operational performance across electronics, pharma, and heavy industries.
| Brand Name: | AirsCooler | Design Standard: | @ASME, PED, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Production standard: | GB150.ASME.European standard. |
Usually 20–30 days after receiving the deposit and confirming drawings/materials.
50% T/T before production, balance before shipment.
One year after shipping (manufacturing defects only; misuse and consumables excluded).
Prices are valid for 30 days due to raw-material fluctuations.
Yes. OEM branding is available (nameplate/logo/label engraving as requested).
Quick production and shipping to minimize compressor downtime.
Exact-fit replacements by part number or drawing, tested for reliability.
Backed by a 12-month warranty and responsive after-sales support.
View Details
View Details
View Details